Home >> Overcurrent

OVERCURRENT PROTECTION

For more than 50 years we have been manufacturing reliable components for protecting T&D networks. Our level of expertise is at your service for the following families of products.


Type K (1 to 200 AMP)
Type K (1 to 200 AMP)

Technical Standards:
IEEE Std C37.41:2016/ IEEE Std C37.42:2016
Fuse Element: Tin or Silver alloy
Speed Ratio: 6 to 8,1
Vulcanized fiber tubes

Data Sheet
Card image cap
Type T (1 to 200 AMP)

Technical Standards:
IEEE Std C37.41:2016/ IEEE Std C37.42:2016
Fuse Element: Tin or Silver alloy
Speed Ratio: 10 to 13,1
Vulcanized fiber tubes

Data Sheet
Type H (1 to 100 AMP)
Type H (1 to 100 AMP)

Technical Standards:
IEEE Std C37.41:2016/ IEEE Std C37.42:2016
Fuse Element: Copper
Speed Ratio: 4,7 to 7,1
Vulcanized fiber tubes

Data Sheet
Type NS (1 to 100 AMP)
Type NS (1 to 100 AMP)

Technical Standards:
IEEE Std C37.41:2016/ IEEE Std C37.42:2016
Fuse Element: Silver alloy
Speed Ratio: 7,2 to 8,3
Vulcanized fiber tubes

Data Sheet
Type VS (1 to 100 AMP)
Type VS (1 to 100 AMP)

Technical Standards:
IEEE Std C37.41:2016/ IEEE Std C37.42:2016
Fuse Element: NTC alloy
Speed Ratio: 18 to 22,3
Vulcanized fiber tubes

Data Sheet
Type SR (0.2 to 46 AMP)
Type SR (0.2 to 46 AMP)

Technical Standards:
IEEE Std C37.41:2016/ IEEE Std C37.42:2016
Fuse Element: NTC alloy
Speed Ratio: 15 to 30
Vulcanized fiber tubes

Data Sheet
Universal Adapter
Universal Adapter

Technical Standards:
IEEE Std C37.41:2016/ IEEE Std C37.42:2016
For double tail Cutouts

Cutout for 15 Kv
Cutout for 15 Kv

COASTAL AREAS OR HIGH POLLUTION
Technical Standards:
IEEE Std C37.41:2016/ IEEE Std C37.42:2016
Austenitic Stainless Steel Fittings 304
Operating voltage: 15 kV
Continuos operation: 100 A
Interrupting capability: Symmetrical: 7.1 kA - Asymmetric 10 kA
BIL: 110 kV
Creepage distance: 800 mm
Fastening hardware: Designed under the compliance with the standard
IEEE C37.42
Hooks opening under load: Compatible with LoadBuster tool
Weight: Approximate 5.5 Kg
Insulators made with silicone *HTV WACKER ®

Data Sheet
CBO Fuse for Street Lights (250 V)
CBO Fuse for Street Lights (250 V)

Technical Standards:
UL 248 - 1:2011 / UL 248 - 4:2000
Voltage: 250 V
(In): 5 & 10 A
(Cl): 3 kA

Data Sheet
QSQ Fuses for Street Lights (600 V)
QSQ Fuses for Street Lights (600 V)

Technical Standards:
UL 248 - 1:2011 / UL 248 - 4:2000
Voltage: 600 V
(In): 5 & 10 A
(Cl): 10 kA

Data Sheet
Fuse Holder Single for Street Lights
Fuse Holder Single for Street Lights

Technical Standards:
UL 4248 - 1:2017 UL 4248 - 4:2007
Holder: Molded Polycarbonate
Hardware: Galvanized and Copper Nickel alloy
Rating: 30 A - 600 V
For Conductors: In between 1.5 - 6mm2

Data Sheet
Fuse Holder Double for Street Lights
Fuse Holder Double for Street Lights

Technical Standards:
UL 4248 - 1:2017 UL 4248 - 4:2007
Holder: Molded Polycarbonate
Hardware: Galvanized and Copper Nickel alloy
Rating: 30 A - 600 V
For Conductors: In between 1.5 - 6mm2

Data Sheet

©2018 Eléctricos Internacional | All Rights Reserved | Web design: Bitonal Publicidad